Water quality sensor, pH, TDS, EC, DO, NTU
A probe in the water and its signal board: TDS, pH, turbidity, dissolved oxygen or conductivity as a voltage, on the maker’s own curve.
- 3 pins
- 2 settings
- In 1 project
The Water quality sensor, pH, TDS, EC, DO, NTU in brief
What it is, and every setting the properties panel gives it.
The water quality probe is five analog boards in one part, chosen by model: DFRobot’s Gravity TDS (SEN0244), turbidity (SEN0189), dissolved oxygen (SEN0237) and EC (DFR0300) kits, and the blue PH-4502C pH board. Each has GND, VCC and OUT, the Gravity boards’ minus, plus and A, the pH board’s G, V+ and Po. On an Uno, VCC goes to 5 V and OUT to any analog pin. On an ESP32 the TDS, oxygen and EC boards run from 3.3 V into an ADC1 pin, but the pH and turbidity boards need 5 V and put out up to 3.76 and 4.2 V, so they need a divider first. The slider is the water, and the output is each maker’s own formula run backwards: 300 ppm reads 0.81 V, pH 7 reads 2.5 V with 0.18 V per pH, clear water 4.2 V on the turbidity board, 8 mg/L of oxygen 1.55 V at 25 C, and EC 164 mV per mS/cm. The temperature property drives the makers’ own compensation; skipping it, so warm water reads high, is the classic mistake. Calibration drift, the pH board’s trimmers and its To and Do pins, response time and noise are not modeled.
- Family
- Sensors
- Pins
- 3
- model
- TDS (SEN0244) (or pH (PH-4502C), turbidity (SEN0189), dissolved oxygen (SEN0237), EC (DFR0300))
- temperature
- 25
3 pins
Named as the editor names them, so a wire lands where you expect it.
-, the PH-4502C's G.+, the PH-4502C's V+.A, the PH-4502C's Po.How to use TDS, pH and turbidity probes with an Arduino
Every one of these boards has three pins and an analog output: GND, VCC (the Gravity boards’ plus, the PH-4502C’s V+) and OUT (A, or Po on the pH board). This monitor puts five of them on one Uno, TDS on A0, pH on A1, turbidity on A2, dissolved oxygen on A3 and conductivity on A4, all from 5 V. The sketch averages 20 readings of each and turns the voltage into the water’s value with the maker’s own formula: pH = 7 + (2.5 - V) / 0.18, for one.
Drag each probe’s slider and the serial monitor follows it to the ADC’s resolution, because the part’s output is that same formula run backwards. The fault everybody hits on the bench is calibration, which the simulator leaves out: each probe here is the typical one. The one it does show is temperature. TDS and EC read about 2 percent high for every degree above 25 C unless the sketch compensates; set the probe’s temperature property and watch.
On an ESP32 the TDS, oxygen and EC boards run from 3.3 V; the pH and turbidity boards need 5 V and put out up to 4.2 V, so they need a divider before an ESP32 pin.
float v = volts(A0);
float ec = 133.42 * v * v * v - 255.86 * v * v + 857.39 * v;
float tds = ec / (1.0 + 0.02 * (waterC - 25.0)) * 0.5;
v = volts(A1);
float ph = 7.0 + (2.5 - v) / 0.18;What is true about the Water quality sensor, pH, TDS, EC, DO, NTU, here
In its help article’s own words: what the simulation gets right, and where it stops.
Modeled
Each output is the maker's own published formula, the one their sample code turns the voltage into the quantity with, run backwards. A sketch that uses that formula reads back the slider's value, to one converter step.
TDS. DFRobot's code: EC = 133.42 V³ - 255.86 V² + 857.39 V (µS/cm),
compensated EC25 = EC / (1 + 0.02 (T - 25)), and TDS = EC25 / 2 ppm. 300 ppm
reads 0.81 V, 1000 ppm 2.16 V; the board tops out at 2.3 V. The slider is the 25 C
figure, the one DFRobot's GravityTDS library reports.
pH. The PH-4502C has no maker's datasheet. Its electrode gives the Nernst slope,
59.16 mV a pH at 25 C, and the board amplifies it; the slope every tutorial uses is
0.18 V a pH (a gain of about 3), with the offset trimmer set so pH 7 reads 2.5 V:
pH = 7 + (2.5 - V) / 0.18. Acid reads higher: pH 4 is 3.04 V, pH 10 is 1.96 V.
The slope follows the absolute temperature, as the Nernst equation says: at 0 C it is
8% smaller.
Turbidity. DFRobot's chart of voltage against turbidity, at 5 V, is the curve
NTU = -1120.4 V² + 5742.3 V - 4352.9: 4.2 V in clear water, 3.9 V at 1000 NTU,
2.63 V at 3000. Murkier reads lower. The wiki says clear water reads 4.1 V give or
take 0.3 V from 10 to 50 C, so temperature does nothing to this model.
Dissolved oxygen. DFRobot's single-point calibration: the voltage is in
proportion to the oxygen, and saturated water (8.25 mg/L at 25 C) reads the
calibration voltage, 1600 mV in their sample, which moves 35 mV a degree:
DO = mV x saturation(T) / (1600 + 35 (T - 25)), with the saturation table from
their code. 8 mg/L at 25 C is 1.55 V. The board's output stops at 3.0 V, which is
15.5 mg/L at 25 C.
EC. The board's gain is documented: 820 ohms of feedback and about 200 mV of
excitation, so DFRobot_EC reads EC = mV / 820 / 200 x 1000 mS/cm (K = 1, before
calibration), compensated by 1 + 0.0185 (T - 25). That is 164 mV per mS/cm: the
1413 µS/cm buffer reads 232 mV and the 12.88 mS/cm buffer 2.11 V.
Not ratiometric. These boards put out their own voltage whatever the supply, so a sketch that reads the converter against a 4.8 V USB supply but assumes 5 V reads a little high.
Not modeled
Calibration. Every real probe is a little different, which is why each maker has a calibration procedure. The model is the maker's typical curve: an ideal probe that has just been calibrated. Calibration drift and electrode aging (the pH and EC electrodes, the DO probe's membrane and filling solution, which DFRobot says to change every month or few) are not modeled.
The PH-4502C's trimmers. Here the offset is always exactly 2.5 V at pH 7 and the
slope exactly 0.18 V a pH at 25 C. The To and Do pins, and the turbidity board's
digital mode and its threshold, are not modeled either.
Response time. The output follows the slider at once. A real DO probe takes up to 90 seconds to reach 98% (DFRobot's figure), the turbidity board up to half a second.
The TDS and EC boards' AC excitation. The real boards drive the probe with an alternating signal, so the electrodes do not polarize, and smooth the result to a DC output. Only that DC output is modeled, along with no polarization at high conductivity, no noise, and none of the probes' stated accuracy (TDS ±10% of full scale, EC ±5%).
From Water quality probe (TDS, pH, turbidity, DO, EC), in full.
See the Water quality sensor, pH, TDS, EC, DO, NTU in a project
One built-in project uses it. It opens in the editor, already wired.
The boards it is shown on
This board has a built-in project with the Water quality sensor, pH, TDS, EC, DO, NTU in it.
The rest of the bench
Every one of these is drawn and simulated the same way.
Wire up the Water quality sensor, pH, TDS, EC, DO, NTU
Open the editor and push it into the breadboard. It is free, and it runs on your own machine.