The Nova Fitness SDS011 talks 9600 baud, 8N1, 3.3 V logic, and sends a ten byte frame on its own. Aliases: SDS011, SDS-011, SDS018, SDS021, Nova Fitness, inovafitness, dust sensor, PM2.5 sensor, particulate matter, air quality sensor.
Pins
| Pin | Name | What it does |
|---|---|---|
| 1 | NC |
Not connected. |
| 2 | PM25 |
PM2.5 as PWM ("1um" on the silkscreen). Not driven here. |
| 3 | 5V |
Supply, 4.7 V to 5.3 V. The fan needs 5 V. |
| 4 | PM10 |
PM10 as PWM ("2.5um" on the silkscreen). Not driven here. |
| 5 | GND |
Ground. |
| 6 | RX |
Commands in, 3.3 V logic. |
| 7 | TX |
Frames out, 3.3 V logic. |
The data frame
Ten bytes: AA C0, PM2.5 low and high byte, PM10 low and high byte, the two byte device
ID, a check that is the low eight bits of the sum of the six data bytes, and AB. The
readings are in tenths: AA C0 D4 04 3A 0A A1 60 1D AB is PM2.5 0x04D4 = 123.6 and
PM10 0x0A3A = 261.8 micrograms per cubic meter.
Commands
Nineteen bytes: AA B4, thirteen data bytes, the device ID (FF FF for any sensor), a
check that is the low eight bits of the sum of bytes 2 to 16, and AB. The first data
byte picks the command; every one but the query is answered AA C5 with the same first
byte.
| Command | First data bytes | What happens |
|---|---|---|
| Reporting mode | 02 01 00 / 02 01 01 |
Active (a frame a second) or query mode. Kept through a power cut. |
| Query data | 04 |
Answered with one data frame. |
| Set device ID | 05, new ID in data bytes 12 and 13 |
Kept through a power cut. |
| Sleep / work | 06 01 00 / 06 01 01 |
Fan and laser off or on. Lost at a power cut. |
| Firmware version | 07 |
Answered with year, month and day. |
| Working period | 08 01 n |
0 continuous, or every n minutes (1 to 30): 30 s of work, then sleep. |
With 00 in place of 01 as the second data byte, a command asks for the setting
instead of changing it. A command for another device ID, or with a wrong check or tail, is
ignored.
Properties
| Property | What it is |
|---|---|
pm25, pm10 |
The dust the sensor reports, 0 to 999.9 micrograms per cubic meter. |
The two sliders on the part set them while it runs. PM10 includes PM2.5, so a PM10 set under the PM2.5 is raised to match.
Libraries
SdsDustSensor.h (the "Nova Fitness Sds dust sensors library" by Paweł Kołodziejczyk, the
one the ESP32 and ESP8266 tutorials use): SdsDustSensor sds(rxPin, txPin) or
sds(Serial1), sds.begin(), then PmResult pm = sds.readPm() and pm.pm25, pm.pm10
when pm.isOk(). setQueryReportingMode() with queryPm(), sleep(), wakeup() and
setCustomWorkingPeriod(n) send the commands above. Or read the frames from Serial
yourself: wait for AA C0, take eight more bytes and check the sum.
What the model gets right
The frame and command layouts, the checks, the answers, the device ID filter, the once a
second reporting, the query and sleep modes, the working period and which settings outlive
a power cut are the Nova Fitness protocol's (V1.3). The device ID starts as the manual's
example, A1 60, and the firmware version is the manual's example, 15-7-10.
What it does not model
There is no fan and no air inside, so the 30 seconds the manual asks for after waking before the data is stable do not apply: the first frame, a second after power on or wake, carries the sliders. The readings are exact, with none of the sensor's 15 percent or 10 microgram error. The PWM pins are not driven, as the specification gives their 1004 ms cycle but no formula. In a working period the frame comes at the end of the 30 seconds of work; the manual says only that the sensor reports the latest data.
Common mistakes
Powering it from 3.3 V: it needs 5 V, and under 4.7 V it says nothing. Crossing the serial
pins the wrong way: the sensor's TX goes to your RX pin. Querying it faster than every 3
seconds in query mode, which the manual advises against. Leaving it running all day: the
laser lasts about 8000 hours, so use a working period or sleep between readings.
See it in action
SDS011 dust monitor reads the frames with the SdsDustSensor library and prints PM2.5 and PM10. Open it at /templates.