KY Hall, reed, temperature and sound boards
The 37-in-1 kit's four-pin LM393 boards: the KY-024 Hall, KY-025 reed, KY-028 thermistor and KY-037 sound modules. DO goes high on detect.
The four-pin boards of the 37-in-1 sensor kit: the KY-024 linear Hall sensor, the KY-025 reed switch, the KY-028 digital temperature sensor and the KY-037 big sound sensor. Aliases: linear magnetic Hall module, reed module, thermistor module, high-sensitivity sound module.
Each is the sensor on an LM393 board with a blue multi-turn trimmer: the sensor comes
out on AO, the comparator compares it with the trimmer, and DO goes high and
lights the second lamp when the sensor is past it.
Pins
| Pin | What it does |
|---|---|
AO |
The sensor's voltage, printed A0. |
GND |
G. |
VCC |
+, 3.3 V to 5 V. |
DO |
High, with the lamp lit, when the sensor is past the trimmer. |
The header order varies between batches; this is the one printed on most, A0 G + D0.
Read your board's silk screen.
The sensors
KY-024. A 49E linear Hall sensor, the same model as the bare 49E:
half the supply with no field, 1.4 mV a gauss on 5 V, up for a south pole at the face.
DO trips only for the pole that lifts AO. threshold is 0.6 by default, 0.5 V
above rest, about 360 G, which the magnet makes at about 7 mm.
KY-025. A normally open reed under a 10 k pull-up, so AO is two levels: the supply
with no magnet and nearly ground with one. It is a switch, not a measurement. It closes
at close mm (15) and opens past close / release (18.75).
KY-028. A 10 k NTC bead (beta 3950, beta) as the lower half of a divider under
10 k, so AO falls as it warms: half the supply at 25 C. DO goes high when it is
warmer than the trimmer; threshold 0.45 trips at about 30 C, a finger on the bead.
KY-037. The KY-038 board with the bigger capsule, a CUI
CMA-6542PF, -42 dB re 1 V/Pa on its sheet: 2 dB more sensitive, and still no
amplifier. A clap pulses DO; talking barely moves AO.
The reed's pull-up and the top of the thermistor's divider are taken as 10 k, the value the listings give. Where a new board's trimmer sits is anyone's guess; the defaults are set so the obvious thing (a magnet, a finger, a clap) trips it.
What it does not model
The reed's fraction of a millisecond of bounce, the bead's thermal lag, and the
comparator's lack of hysteresis, which makes a real DO chatter right at the trimmer.
Common mistakes
Reading the KY-025's AO as a field strength. It only says closed or open.
Reading the KY-028 as a thermometer from DO. DO is a thermostat; read AO and work
the temperature out from the bead's beta for a number.
See it in action
KY comparator boards and an IR switch reads each D0 on pins 2 to 5 and prints
what it sees. Open it at /templates.