Before you start
This is an advanced course. The quarter, half and full bridge, the thermistor and the HX711's tare and calibration belong to Sensors and measurement, and the instrumentation amp to the Op-amp circuit cookbook. This course links back rather than teaching them again.
Take the course Sensor signal conditioning on /learn.
The chips
Three lessons run gallery sketches on an Uno: the HX711 kitchen scale, and the kiln and bath probes, a MAX31855 thermocouple converter beside a MAX31865 PT100 converter. The HX711's input noise is set to zero so every run prints the same grams; a real one wanders by about twenty counts.
The analog benches
Mokxi has no analog load cell, thermocouple or RTD part (the chip parts keep their sensors inside), so the benches use honest stand-ins: a thermocouple is a bench supply set to its EMF from the NIST type K table, a PT100 is a resistor set to its IEC 60751 resistance, and the boss's load cell is its electrical model, two 2.5 V outputs behind 350 ohms with the load's millivolts between them. The amplifiers are an OP07 for the thermocouple and LM358s everywhere else.
The lessons
- Wheatstone bridges in practice: mV/V, a bridge that bends, lead wires that fake a strain, the three-wire fix and shunt calibration.
- Load cells and the HX711: the counts behind a gram, the wrong cell, mV/V over capacity, and an overloaded input.
- Thermocouples: the cold junction, compensation that follows the room, the curve at 500 C, and the MAX31855.
- RTDs: 0.385 ohm per degree, two wires that lie, four that do not, self-heating, and the MAX31865.
- Offset and gain: zero and span onto an ADC, and the floor and ceiling of a single-supply op-amp.
- Anti-alias filters: Nyquist and folding, one pole against two, and capacitors in the wrong ratio.
- Boss build: a precision scale: an LM358 in-amp and an HX711 on the same load, a zero error trimmed out, and a redesign for a 20 kg cell.