None of these projects is a medical device. They are learning projects: never use them to diagnose anything, to decide on treatment, or to reassure anyone who feels unwell. Anything touching skin runs from a battery only (a USB power bank, or a laptop unplugged from the wall), never from mains.
Take the course at /learn/path/health-and-biometric-sensors. It is an intermediate course: it assumes the Uno course.
The lessons
Heart. A MAX30102 in one lesson for pulse and SpO2: the steady light level, the pulse swing on top, Maxim's heart rate and SpO2, and a finger threshold that is only a guess. An AD8232 ECG: R spikes found with a threshold and a refractory time, the R-R interval, leads off, noise, and a refractory time too long for a fast heart.
Skin and body. A GSR module in microsiemens with a tonic level and phasic responses, and what skin response cannot say. An MLX90614 reading object and ambient, skin that is not the core, and a hot-surface warning.
Identity and honesty. A fingerprint module that keeps its templates and returns an ID and a confidence, and why fingerprints are not passwords. Then the oximeter again with honest rules: no finger, no number; the settling window thrown away; readings outside what the method can measure refused.
Boss. A fitness monitor: MAX30102, MLX90614 and an SSD1306 on one I2C bus, heart rate zones from 220 minus age, a peak, and every honest rule kept.
The benches
The PPG and limits lessons open the oximeter (MAX30102 at 0x57), the ECG lesson the ECG plot (OUTPUT on A0, LO+ 10, LO- 11), the GSR lesson the lie detector's first stage (GSR on A0, a bar on 2 to 11), the temperature lesson the fever thermometer (MLX90614 at 0x5A) and the fingerprint lesson the fingerprint lock (pins 2 and 3). The boss has the MAX30102, the MLX90614 and an SSD1306 at 0x3C on A4 and A5.
What each sketch does
bioppg: four-second windows, the IR level and swing, Maxim's algorithm, andFINGER_IR.bioecg:THRESHOLD,REFRACTORY_MS, an average of four R-R intervals, and LO+ and LO-.biogsr: the module's formula, a slow tonic average, andRESPONSE_US.biotemp: object and ambient, andHOT_C.biofinger: image, template, fast search, andADMIN_ID.biolimits:SETTLE_WINDOWS,BPM_LOW,BPM_HIGHandSPO2_LOW.bioboss:AGE, zones, a peak, and the OLED through SSD1306Ascii.
Honest limits
- The simulated finger, skin and heart are clean signals: no movement, cold fingers, skin tone, nail polish or room light.
- The MAX30102's first window includes its start-up, and windows that span a change mix the two rates: both are real behavior of the method.
- The MLX90614's emissivity setting is accepted but does not change the reading.
- Every fingerprint match has a confidence of 100.
Related
Build a science fair lie detector uses the GSR and MAX30102 for a demo, said plainly.