Take the course at /learn/path/water-level-and-flow. It is an intermediate course on the Uno.
Low voltage only. Everything here runs on 5 V and 12 V DC. A mains pump, a mains float switch or anything plugged into the wall is a job for a licensed electrician, with a GFCI and a rated enclosure, never a hobby relay board.
The bench
Each lesson uses the parts it needs: a high float on pin 4 and a low float
on pin 5 (to ground, read with INPUT_PULLUP), an HC-SR04 in a tank lid
(TRIG 6, ECHO 7), a YF-S201 on interrupt pin 2, the kit water sensor as a
leak probe on A0 powered from pin 8, a buzzer on pin 12, and a relay module
on pin 10 whose COM and NO contacts switch a 12 V adapter to an R385
diaphragm pump.
The lessons
Float switches. EMPTY, PART and FULL from two floats, a fault for the state that cannot happen, and a float turned over to NC so a broken wire fails safe.
Ultrasonic tank level. Echo time to millimeters to liters in a 400 mm tank, the dead zone, and a hot day: at 35 C a sketch that assumes 20 C reads 3.5 L for 3.0.
YF-S201 flow. 7.5 pulses a second per L/min, 450 a liter, counted with an interrupt, and a batch that closes late because it looks once a second.
Leak probes. Powered for 10 ms a second so the traces last, a buzzer, and a latch for the leak that dried before anyone looked.
Pumps on relays. Why a pin cannot run a pump, a relay switching the pump's own 12 V supply, and a rest time against short cycling.
Dry-run protection. No flow within the priming time, or flow lost, stops the pump until a person retries.
Boss: a sump controller. Two floats as hysteresis, a dry-run guard, a high-water alarm, a maximum run time and a lockout.
The sketches
| Sketch | What it does |
|---|---|
wtxfloat |
Two floats: EMPTY, PART, FULL and a fault |
wtxsonar |
HC-SR04 tank level in millimeters and liters |
wtxflow |
YF-S201 flow, total and a batch |
wtxleak |
A leak probe powered only to read, with a latch |
wtxpump |
A 12 V pump on a relay, with a rest time |
wtxdry |
The dry-run guard |
wtxsump |
The sump controller |
What the simulation leaves out
The parts do not share water: the floats, the flow sensor and the
ultrasonic target do not follow the pump, so the lessons ask you to move
them as the water would. The water sensor's reading does not change with how
conductive the water is, and corrosion is not modeled. Relay contact bounce
and arcing are not modeled. The water quality probe (waterprobe) measures
TDS, pH and the like rather than whether water is present, so the leak
lesson uses the kit water sensor instead.
Related
The float switch, the YF-S201, the water level sensor, the water pump, the relay and the HC-SR04.