PZEM004Tv30: an AC energy meter over Modbus
Yes. You can use the PZEM004Tv30 library online in Mokxi with nothing to install, and the sketch runs in your browser against the simulated part (AC energy meter, PZEM-004T v3.0). The example below, "Volts, amps, watts and kWh from a PZEM-004T with PZEM004Tv30", runs on the Arduino Uno R3.
Built in on Mokxi: #include <PZEM004Tv30.h> and it builds, with nothing to install. Free, and no account needed.
What PZEM004Tv30 does
The PZEM-004T v3.0 is a module that meters mains power. It measures the AC voltage across its terminals and the current through its coil, and reports voltage, current, real power, accumulated energy, frequency and power factor over a TTL serial line using Modbus-RTU. Jakub Mandula’s PZEM004Tv30 library turns each value into one function call.
The calls cost less than they look. Each one reads all ten measurement registers in a single request and caches them, and the others return the cached values for the next 200 ms, so reading all six in a row is one trip on the wire. A failed read, meaning no answer or a bad CRC within 100 ms, returns NAN, which is the first thing to test for. The energy count lives in the meter and keeps growing until resetEnergy() clears it.
The example uses SoftwareSerial on an Uno, with the meter’s TX into pin 2 and its RX from pin 3. A Mega can use Serial1 to Serial3, and a classic ESP32 reaches the meter with PZEM004Tv30 pzem(Serial2, 16, 17). On the ESP32-S3, C3 and C6 boards in Mokxi, Serial1 and Serial2 share the serial monitor, so a meter there is never reached and every reading is NAN. In Mokxi the mains values are sliders on the pzem004t part; on a real build the AC side carries mains voltage and belongs in a closed enclosure.
| Library Manager name | PZEM004Tv30 |
|---|---|
| Author | Jakub Mandula |
| Include | #include <PZEM004Tv30.h> |
| Boards | Arduino Uno, Arduino Nano, Arduino Mega 2560, Arduino Leonardo, SparkFun Pro Micro, Arduino Micro, Arduino Pro Mini 3.3 V, ESP8266 NodeMCU |
| In the simulator | Simulated: it runs against the part the way it does on the bench. |
| Parts it drives | AC energy meter, PZEM-004T v3.0 |
Install it
It builds on Arduino Uno, Arduino Nano, Arduino Mega 2560, Arduino Leonardo, SparkFun Pro Micro, Arduino Micro, Arduino Pro Mini 3.3 V, ESP8266 NodeMCU.
In Mokxi it is built in: #include <PZEM004Tv30.h> and the sketch compiles, with no download, no zip and no Library Manager.
On a real board, install "PZEM004Tv30" by Jakub Mandula from the Arduino IDE’s Library Manager (Sketch, Include Library, Manage Libraries), or add PZEM004Tv30 to lib_deps in PlatformIO. Mokxi follows the calls of release 1.2.1, so a sketch written here builds there too.
What to know in the simulator: The mains is set on the part’s sliders. On the classic ESP32 boards PZEM004Tv30 pzem(Serial2, 16, 17) talks to it over the real UART2.
The calls you will use
In the order a sketch meets them.
PZEM004Tv30 pzem(pzemSWSerial)
Creates the driver on a SoftwareSerial port, declared as SoftwareSerial pzemSWSerial(2, 3), and starts it at 9600 baud. A second argument picks a meter address.
PZEM004Tv30 pzem(Serial2, 16, 17)
The classic ESP32 form: a hardware UART with its RX and TX pins.
pzem.voltage()
RMS voltage in volts, or NAN when the meter did not answer.
float voltage = pzem.voltage();
if (isnan(voltage)) {
Serial.println("Error reading voltage");
}pzem.current()
Current in amps; pzem.power() is real power in watts.
pzem.energy()
Energy counted since the last reset, in kWh. Print it with three decimals to see small loads add up.
pzem.pf()
Power factor from 0 to 1; pzem.frequency() is the mains frequency in Hz.
pzem.resetEnergy()
Clears the meter’s energy counter and returns true when the meter confirms.
pzem.setAddress(0x01)
Gives a meter its own Modbus address so several can share one serial line. readAddress() asks the meter for its current one.
pzem.setPowerAlarm(1500)
Sets an alarm threshold in watts. getPowerAlarm() returns true while power is above it.
Example: Volts, amps, watts and kWh from a PZEM-004T with PZEM004Tv30
On the Arduino Uno R3. It runs in the browser exactly as printed.
#include <PZEM004Tv30.h>
#include <SoftwareSerial.h>
// The meter's TX into the first pin, its RX from the second.
SoftwareSerial pzemSWSerial(2, 3);
PZEM004Tv30 pzem(pzemSWSerial);
void setup() {
Serial.begin(115200);
delay(250); // the library skips reads in its first 200 ms
}
void loop() {
Serial.print("Custom Address:");
Serial.println(pzem.readAddress(), HEX);
float voltage = pzem.voltage();
float current = pzem.current();
float power = pzem.power();
float energy = pzem.energy();
float frequency = pzem.frequency();
float pf = pzem.pf();
if (isnan(voltage)) {
Serial.println("Error reading voltage");
} else {
Serial.print("Voltage: "); Serial.print(voltage); Serial.println("V");
Serial.print("Current: "); Serial.print(current); Serial.println("A");
Serial.print("Power: "); Serial.print(power); Serial.println("W");
Serial.print("Energy: "); Serial.print(energy, 3); Serial.println("kWh");
Serial.print("Frequency: "); Serial.print(frequency, 1); Serial.println("Hz");
Serial.print("PF: "); Serial.println(pf);
}
Serial.println();
delay(2000);
}Wiring
- Arduino Uno R3 2 to AC energy meter, PZEM-004T v3.0 TX
- Arduino Uno R3 3 to AC energy meter, PZEM-004T v3.0 RX
- Arduino Uno R3 5V to AC energy meter, PZEM-004T v3.0 5V
- Arduino Uno R3 GND to AC energy meter, PZEM-004T v3.0 GND
Common errors and how to fix them
Error reading voltage
voltage() returned NAN because no valid answer came back. Check that the meter’s TX goes to the board’s receive pin and its RX to the transmit pin, and that the SoftwareSerial pins match the wiring.
The first reading after reset is 0
The library skips reads during its first 200 ms. Put delay(250) in setup() before the first call, as the example does.
Two meters on one line return the same values, or garbage
Both answer the general address 0xF8. Connect one meter at a time and call setAddress() to give each a different address, then create one PZEM004Tv30 object per address.
Every reading is NAN on an ESP32-S3, C3 or C6
On those boards in Mokxi, Serial1 and Serial2 share the serial monitor rather than reaching the part. Use a classic ESP32 with Serial2 on pins 16 and 17, or an Uno or Mega.
Questions and answers
Why is energy 0.000 kWh when the example starts?
The count starts from zero on a fresh meter and grows as power flows. At 480 W it takes a while to show in the third decimal place.
Can I test PZEM code without connecting to mains?
In Mokxi, yes: the pzem004t part’s sliders set the voltage, current, power factor and frequency, and the sketch reads them over the same Modbus requests.
Projects that use PZEM004Tv30
Built-in projects that include it. Each page has the full sketch and opens in the editor, already wired.
Keep going
Try PZEM004Tv30 without installing anything
Open the example, change the sketch, and keep your version in a free account.