Find your kit
Pick the starter kit you own and run every lesson in its manual with the same parts on the same pins.
See every kitThe motor starter an industrial electrician gets called to: read the ladder, find opens with the voltage method and hopscotch, tell coils from contacts, handle overloads and intermittents, and fix a dead conveyor with three faults on it.
0 of 7 done
7 lessons in 7 chapters, about 6 hours on a simulated breadboard. Free, in your browser, every step checked by the simulator.
Each lesson opens when the one before it is done, and each chapter ends in a project.
Rails, rungs, wire numbers, and where 24 V should be.
A 24 V conveyor starter drawn as a ladder: rails, rungs, wire numbers, a coil and its contacts. Run it, start it, stop it, and read where the voltage sits on each wire.
0 of 6 steps
Measure across each device: the open reads the whole supply.
The conveyor will not start. Measure across each device on the dead rung: closed ones read nothing, the coil reads nothing because no current flows, and the open reads the whole supply.
0 of 6 steps
One lead on L2, the other hopping until the voltage vanishes.
One lead parked on L2, the other hopping from wire number to wire number along the rung. Voltage is there until you jump past the open; then it is gone.
0 of 6 steps
An open coil, a burnt contact under load, and a welded one.
A coil with 24 V across it that never pulls in, then a contactor that runs the motor slow: an open coil proved on the ohms range, and a burnt contact found by measuring it under load.
0 of 6 steps
Read a trip, set the dial from the motor, never reset into a jam.
An overload that trips the instant START is pressed, then a jam that trips it for real. Read the trip, set the dial from the motor's current, measure the running amps, and never reset into a jam.
0 of 6 steps
Why a blink is a stop, the wiggle test and the loose terminal.
A conveyor that stops on its own once a shift and runs fine when you get there. Why a split-second open stops a seal-in circuit for good, the wiggle test, and catching the loose terminal on the meter.
0 of 7 steps
Three faults, one dangerous, and a pull-cord stop to finish.
A repair ticket on the packing line: the conveyor is dead. Three faults stand between you and a running belt, one of them dangerous. Find each with the meter, fix it, verify, then add a pull-cord stop.
0 of 8 steps
All 7 lessons, in order, each with what it covers. Any of them opens in the editor right away.
Every lesson runs in the simulator with nothing to buy. When you want the real thing, these kits have the parts.
Pick the starter kit you own and run every lesson in its manual with the same parts on the same pins.
See every kitYes. All 7 lessons of Troubleshooting control circuits are free and run in your browser, with nothing to install and no parts to buy before you start.
No. Every circuit is built on a simulated breadboard, and the simulator checks each step as you go. When you want to build it for real, the same parts and wiring work on a real bench.
About 6 hours: 7 lessons in 7 chapters, each one a few short steps. Your progress is kept, so you can stop after any lesson and pick up where you left off.
With "Reading the ladder", and each lesson builds on the one before it. New to circuits? Electronics basics is the course that starts from zero.