Find your kit
Pick the starter kit you own and run every lesson in its manual with the same parts on the same pins.
See every kitHow a burglar alarm thinks: NC loops, end-of-line and supervised zones, sirens and strobes, keypads and arming, battery backup, and a four-zone panel you wire and make your own.
0 of 7 done
7 lessons in 7 chapters, about 6 hours on a simulated breadboard. Free, in your browser, every step checked by the simulator.
Each lesson opens when the one before it is done, and each chapter ends in a project.
Contacts in series that fail safe, and an NO button that fails silently.
Three door contacts in series hold a MOSFET off: open any door and the alarm lamp lights, cut the wire and it lights too. The same test on a normally open panic button shows why alarms fail safe.
0 of 7 steps
A resistor at the far end lets the panel see a jumper.
A 4.7k resistor at the far end of the loop gives the panel a middle voltage to expect: a door reads high, a burglar's jumper reads low, and a plain loop cannot tell the jumper from a shut door.
0 of 6 steps
Double end-of-line: normal, open, cut and short on two wires.
Double end-of-line wiring: a resistor in series and another across the contact give a panel four voltages, so it tells a shut door, an open door, a cut wire and a short apart.
0 of 5 steps
A MOSFET bell output, its current, and the run that silences a siren.
A MOSFET switches a 12 V siren and a strobe at the end of a wire run: their current, why a long thin run can silence a siren, and adding a second siren to the bell output.
0 of 6 steps
An Uno panel: away, stay, exit and entry delays, and not-ready zones.
An Uno reads three DEOL zones on its analog pins, a PIR and a 4x4 keypad: arm away, the exit delay, not-ready zones, the entry delay, an alarm with siren and strobe, and arming stay.
0 of 7 steps
A float charger and a lead-acid battery that take over without a gap.
A 13.8 V charger, a 12 V 7 Ah lead-acid battery and a panel on one bus: watch the battery current change sign when the power fails, carry the siren, and drain, and work out standby time.
0 of 6 steps
Wire a zone, walk test, change the code, bypass, catch a tamper, set the bell cutoff.
Wire the window's DEOL loop, walk test every zone, change the master code, bypass a zone, catch a tamper and set your own bell cutoff: a four-zone panel with keypad, siren and strobe, made yours.
0 of 8 steps
All 7 lessons, in order, each with what it covers. Any of them opens in the editor right away.
Every lesson runs in the simulator with nothing to buy. When you want the real thing, these kits have the parts.
Pick the starter kit you own and run every lesson in its manual with the same parts on the same pins.
See every kitYes. All 7 lessons of Low-voltage alarm circuits are free and run in your browser, with nothing to install and no parts to buy before you start.
No. Every circuit is built on a simulated breadboard, and the simulator checks each step as you go. When you want to build it for real, the same parts and wiring work on a real bench.
About 6 hours: 7 lessons in 7 chapters, each one a few short steps. Your progress is kept, so you can stop after any lesson and pick up where you left off.
With "Normally closed loops: why alarms are wired backwards", and each lesson builds on the one before it. New to circuits? Electronics basics is the course that starts from zero.