See every kitWhy wire gets hot and how to stop it: copper resistance, ampacity, voltage drop, fuse curves, thermal and magnetic breakers, coordination, and a 12 V camper circuit you size yourself.
0 of 7 done
7 lessons in 7 chapters, about 5 hours on a simulated breadboard. Free, in your browser, every step checked by the simulator.
Each lesson opens when the one before it is done, and each chapter ends in a project.
Every wire is a resistor: the AWG table, the round trip, and hot copper.
A 12 V supply feeds a light bar through a run of wire: the AWG table in ohms per 1000 ft, why the run counts twice, how gauge, length and heat change the volts that arrive.
0 of 6 steps
Heat is I squared R, and the insulation sets the limit.
Thin and thick wire carrying the same current: heat is I squared times R, why 1.5 times the current is 2.25 times the heat, what the ampacity tables mean, and a filament as a wire run hot on purpose.
0 of 6 steps
An Uno computes the drop for a gauge, a length and a load.
An Uno computes the round-trip drop for a gauge, a length and a load, flags 3 and 5 percent, names the smallest wire that fits, and checks its own math on a scaled bench stand-in.
0 of 7 steps
A real fuse blows on a short, a current limit saves it, and inrush fools it.
A meter's own fuse blows on a dead short, a current-limited supply keeps it alive, and five cold lamps blow a fuse four times their running current: inrush, time-current curves, fast and time-delay fuses.
0 of 7 steps
An inverse-time thermal trip, a hot reset refused, and the magnetic trip.
An Uno runs an inverse-time overload on a motor: a jam trips in seconds, a mild overload takes much longer, and a hot trip refuses to reset. Then the magnetic trip and the B, C and D curves.
0 of 6 steps
Branch breakers against a main, and a fused feeder that clears the right fault.
A panel monitor checks four branch circuits against their breakers and a main, then a fused 12 V feeder shows why the device nearest the fault must open first, and what a fault upstream of it does.
0 of 7 steps
Size a 12 V camper circuit: load, fuse, wire, drop and a fault test.
Size a real 12 V branch from scratch: add up the load, pick the fuse with the 125 percent rule, pick the gauge for 3 percent drop, prove the fuse clears a chafed wire, then resize it for a longer run.
0 of 7 steps
All 7 lessons, in order, each with what it covers. Any of them opens in the editor right away.
Every lesson runs in the simulator with nothing to buy. When you want the real thing, these kits have the parts.
Pick the starter kit you own and run every lesson in its manual with the same parts on the same pins.
See every kitYes. All 7 lessons of Wire, fuses and breakers are free and run in your browser, with nothing to install and no parts to buy before you start.
No. Every circuit is built on a simulated breadboard, and the simulator checks each step as you go. When you want to build it for real, the same parts and wiring work on a real bench.
About 5 hours: 7 lessons in 7 chapters, each one a few short steps. Your progress is kept, so you can stop after any lesson and pick up where you left off.
With "Copper resistance: every wire is a resistor", and each lesson builds on the one before it. New to circuits? Electronics basics is the course that starts from zero.