All paths

MQ gas sensors, honestly

Heaters, Rs/R0, calibration, cross sensitivity and alarms on the cheap MQ sensors, and why a hobby build never replaces a listed detector.

Arduino Uno R3Free7 lessons6 h4 chapters2,335 XPEmbedded engineering · Intermediate+150 XP

0 of 7 done

What you will build

3 projects, built step by step

7 lessons in 4 chapters, about 6 hours on a simulated Arduino Uno R3. Free, in your browser, every step checked by the simulator.

Chapter 1 project

Rs/R0 ratios

Turn AO into the element's resistance, then into the ratio the datasheet's chart is drawn in, then into parts per million.

Open it in the simulator
Chapter 2 project

Cross sensitivity

Every MQ sensor answers to many gases and cannot say which one it smells. Fool all three sensors on the bench.

Open it in the simulator
Chapter 3 project

What a listed detector does

A CO alarm listed to UL 2034 decides by exposure over time, sounds a set pattern, tests itself and reports faults. Sketch the ideas, and learn why a sketch is never the alarm.

Open it in the simulator
The map

Chapter by chapter

Each lesson opens when the one before it is done, and each chapter ends in a project.

Chapter 1

How the sensor works

A heated tin dioxide film, its warm-up, and the ratio its chart is drawn in.

  1. Open218 XP

    The heater and burn-in

    Inside an MQ sensor is a heater and a film of tin dioxide. Watch a cold one read as gas, then settle, and learn why every gas sketch waits.

    0 of 6 steps

  2. ProjectLocked436 XP

    Rs/R0 ratios

    Turn AO into the element's resistance, then into the ratio the datasheet's chart is drawn in, then into parts per million.

    0 of 6 steps

5 questions, graded as you go.
Chapter 2

Readings that mean something

Measure R0, and learn which gas a reading can and cannot name.

  1. Locked218 XP

    Calibration in clean air

    R0 varies by a factor of two or more between sensors. Measure it in clean air, and see what trusting the datasheet's typical value costs.

    0 of 6 steps

  2. ProjectLocked436 XP

    Cross sensitivity

    Every MQ sensor answers to many gases and cannot say which one it smells. Fool all three sensors on the bench.

    0 of 6 steps

5 questions, graded as you go.
Chapter 3

Alarms, honestly

Hysteresis, exposure over time, test buttons and faults, and what a listing means.

  1. Locked249 XP

    Alarms with hysteresis

    A reading that hovers near a threshold turns a simple alarm on and off all day. Two thresholds fix it.

    0 of 7 steps

  2. ProjectLocked498 XP

    What a listed detector does

    A CO alarm listed to UL 2034 decides by exposure over time, sounds a set pattern, tests itself and reports faults. Sketch the ideas, and learn why a sketch is never the alarm.

    0 of 7 steps

5 questions, graded as you go.
Chapter 4

Boss

A garage fume alarm that knows what it is not.

  1. Locked280 XP

    Boss: a garage fume alarm

    Put it together: warm-up lockout, calibration at boot, a fan on CO, a dose alarm, a fuel vapor alarm and a test button. A project that sits beside listed alarms, never in their place.

    0 of 8 steps

4 questions, graded as you go.
Syllabus

Every lesson in the course

All 7 lessons, in order, each with what it covers. Any of them opens in the editor right away.

Chapter 1

How the sensor works

  1. The heater and burn-inInside an MQ sensor is a heater and a film of tin dioxide. Watch a cold one read as gas, then settle, and learn why every gas sketch waits.
  2. Rs/R0 ratiosTurn AO into the element's resistance, then into the ratio the datasheet's chart is drawn in, then into parts per million.
Chapter 2

Readings that mean something

  1. Calibration in clean airR0 varies by a factor of two or more between sensors. Measure it in clean air, and see what trusting the datasheet's typical value costs.
  2. Cross sensitivityEvery MQ sensor answers to many gases and cannot say which one it smells. Fool all three sensors on the bench.
Chapter 3

Alarms, honestly

  1. Alarms with hysteresisA reading that hovers near a threshold turns a simple alarm on and off all day. Two thresholds fix it.
  2. What a listed detector doesA CO alarm listed to UL 2034 decides by exposure over time, sounds a set pattern, tests itself and reports faults. Sketch the ideas, and learn why a sketch is never the alarm.
Chapter 4

Boss

  1. Boss: a garage fume alarmPut it together: warm-up lockout, calibration at boot, a fan on CO, a dose alarm, a fuel vapor alarm and a test button. A project that sits beside listed alarms, never in their place.
Kits

Build it on your bench too

Every lesson runs in the simulator with nothing to buy. When you want the real thing, these kits have the parts.

Have a kit already?

Find your kit

Pick the starter kit you own and run every lesson in its manual with the same parts on the same pins.

See every kit
Questions

About MQ gas sensors, honestly

Is MQ gas sensors, honestly free?

Yes. All 7 lessons of MQ gas sensors, honestly are free and run in your browser, with nothing to install and no parts to buy before you start.

Do I need a real Arduino Uno R3?

No. Every lesson runs on a simulated Arduino Uno R3 with its parts on the canvas, and the simulator checks each step as you go. When you want to build it for real, the same wiring and code work on a real board.

How long does MQ gas sensors, honestly take?

About 6 hours: 7 lessons in 4 chapters, each one a few short steps. Your progress is kept, so you can stop after any lesson and pick up where you left off.

What will I build?

Each chapter ends in a project that puts it together: Rs/R0 ratios, Cross sensitivity and What a listed detector does.

Where do I start?

With "The heater and burn-in", and each lesson builds on the one before it. New to circuits? Electronics basics is the course that starts from zero.