# Troubleshooting control circuits

The motor starter an industrial electrician gets called to: read the ladder, find opens with the voltage method and hopscotch, tell coils from contacts, handle overloads and intermittents, and fix a dead conveyor with three faults on it.

Free 7 lessons 6 h 7 chapters 2,038 XP Electrical · Advanced +250 XP

0 of 7 done

Start the course free Reading the ladder Lesson plan for teachers

What you will build

## 0 projects, built step by step

7 lessons in 7 chapters, about 6 hours on a simulated breadboard. Free, in your browser, every step checked by the simulator.

The map

## Chapter by chapter

Each lesson opens when the one before it is done, and each chapter ends in a project.

Chapter 1

## Reading the ladder

Rails, rungs, wire numbers, and where 24 V should be.

Open 265 XP

### Reading the ladder

A 24 V conveyor starter drawn as a ladder: rails, rungs, wire numbers, a coil and its contacts. Run it, start it, stop it, and read where the voltage sits on each wire.

0 of 6 steps

Start What is in it

4 questions, graded as you go.

Chapter 2

## The voltage method

Measure across each device: the open reads the whole supply.

Locked 288 XP

### The voltage method

The conveyor will not start. Measure across each device on the dead rung: closed ones read nothing, the coil reads nothing because no current flows, and the open reads the whole supply.

0 of 6 steps

4 questions, graded as you go.

Chapter 3

## Hopscotch testing

One lead on L2, the other hopping until the voltage vanishes.

Locked 288 XP

### Hopscotch testing

One lead parked on L2, the other hopping from wire number to wire number along the rung. Voltage is there until you jump past the open; then it is gone.

0 of 6 steps

3 questions, graded as you go.

Chapter 4

## Failed coils and contacts

An open coil, a burnt contact under load, and a welded one.

Locked 265 XP

### Failed coils and contacts

A coil with 24 V across it that never pulls in, then a contactor that runs the motor slow: an open coil proved on the ohms range, and a burnt contact found by measuring it under load.

0 of 6 steps

4 questions, graded as you go.

Chapter 5

## Overloads

Read a trip, set the dial from the motor, never reset into a jam.

Locked 265 XP

### Overloads

An overload that trips the instant START is pressed, then a jam that trips it for real. Read the trip, set the dial from the motor's current, measure the running amps, and never reset into a jam.

0 of 6 steps

4 questions, graded as you go.

Chapter 6

## Intermittents

Why a blink is a stop, the wiggle test and the loose terminal.

Locked 303 XP

### Intermittents

A conveyor that stops on its own once a shift and runs fine when you get there. Why a split-second open stops a seal-in circuit for good, the wiggle test, and catching the loose terminal on the meter.

0 of 7 steps

4 questions, graded as you go.

Chapter 7

## Boss: fix a dead conveyor

Three faults, one dangerous, and a pull-cord stop to finish.

Locked 364 XP

### Boss: fix a dead conveyor

A repair ticket on the packing line: the conveyor is dead. Three faults stand between you and a running belt, one of them dangerous. Find each with the meter, fix it, verify, then add a pull-cord stop.

0 of 8 steps

3 questions, graded as you go.

Syllabus

## Every lesson in the course

All 7 lessons, in order, each with what it covers. Any of them opens in the editor right away.

Chapter 1

### Reading the ladder

- Reading the ladder A 24 V conveyor starter drawn as a ladder: rails, rungs, wire numbers, a coil and its contacts. Run it, start it, stop it, and read where the voltage sits on each wire.

Chapter 2

### The voltage method

- The voltage method The conveyor will not start. Measure across each device on the dead rung: closed ones read nothing, the coil reads nothing because no current flows, and the open reads the whole supply.

Chapter 3

### Hopscotch testing

- Hopscotch testing One lead parked on L2, the other hopping from wire number to wire number along the rung. Voltage is there until you jump past the open; then it is gone.

Chapter 4

### Failed coils and contacts

- Failed coils and contacts A coil with 24 V across it that never pulls in, then a contactor that runs the motor slow: an open coil proved on the ohms range, and a burnt contact found by measuring it under load.

Chapter 5

### Overloads

- Overloads An overload that trips the instant START is pressed, then a jam that trips it for real. Read the trip, set the dial from the motor's current, measure the running amps, and never reset into a jam.

Chapter 6

### Intermittents

- Intermittents A conveyor that stops on its own once a shift and runs fine when you get there. Why a split-second open stops a seal-in circuit for good, the wiggle test, and catching the loose terminal on the meter.

Chapter 7

### Boss: fix a dead conveyor

- Boss: fix a dead conveyor A repair ticket on the packing line: the conveyor is dead. Three faults stand between you and a running belt, one of them dangerous. Find each with the meter, fix it, verify, then add a pull-cord stop.

Kits

## Build it on your bench too

Every lesson runs in the simulator with nothing to buy. When you want the real thing, these kits have the parts.

Have a kit already?

### Find your kit

Pick the starter kit you own and run every lesson in its manual with the same parts on the same pins.
See every kit

Questions

## About Troubleshooting control circuits

Is Troubleshooting control circuits free?

Yes. All 7 lessons of Troubleshooting control circuits are free and run in your browser, with nothing to install and no parts to buy before you start.

Do I need any parts?

No. Every circuit is built on a simulated breadboard, and the simulator checks each step as you go. When you want to build it for real, the same parts and wiring work on a real bench.

How long does Troubleshooting control circuits take?

About 6 hours: 7 lessons in 7 chapters, each one a few short steps. Your progress is kept, so you can stop after any lesson and pick up where you left off.

Where do I start?

With "Reading the ladder", and each lesson builds on the one before it. New to circuits? Electronics basics is the course that starts from zero.