Source: https://mokxi.com/learn/path/ac-power-fundamentals
Updated: 2026-11-20

All paths

# AC power

Why volts times amps is not watts: phasors, reactance, impedance, real, reactive and apparent power, power factor, correction capacitors, and a motor's power bill, all on a 12 V bench.

Free 7 lessons 6 h 7 chapters 1,593 XP Electrical · Intermediate +150 XP

0 of 7 done

Start the course free Phasors without fear Lesson plan for teachers

What you will build

## 0 projects, built step by step

7 lessons in 7 chapters, about 6 hours on a simulated breadboard. Free, in your browser, every step checked by the simulator.

The map

## Chapter by chapter

Each lesson opens when the one before it is done, and each chapter ends in a project.

Chapter 1

## Phasors without fear

Two AC voltages that add up as a right triangle.

Open 218 XP

### Phasors without fear

A scaled motor on 12 V AC: the resistor and the inductor read 7.2 V and 9.6 V, which add up to 12 V only as the sides of a right triangle. Phasors, the phase angle, and what frequency does to it.

0 of 6 steps

Start What is in it

4 questions, graded as you go.

Chapter 2

## Reactance

Ohms that grow with frequency in a coil and shrink in a capacitor.

Locked 218 XP

### Reactance: ohms that depend on frequency

An inductor and a capacitor, each alone on 12 V at 60 Hz: both draw 30 mA, so both are worth 400 ohms. Double the frequency and the inductor halves its current while the capacitor doubles it.

0 of 6 steps

4 questions, graded as you go.

Chapter 3

## Impedance

Resistance and reactance at right angles, and a capacitor that cancels a coil.

Locked 236 XP

### Impedance: the whole opposition

The motor bench with a capacitor waiting in series: Z = V / I = 500 ohms, the square root of R squared plus X squared, a capacitor that raises the current, one that cancels the inductor, and one that makes the load capacitive.

0 of 6 steps

4 questions, graded as you go.

Chapter 4

## Real, reactive and apparent

Watts, var and VA, and the triangle they make.

Locked 218 XP

### Real, reactive and apparent power

Volts times amps is not watts on AC: the bench takes 0.287 VA, the resistor turns 0.171 W into heat and the inductor borrows 0.229 var and gives it back. The power triangle, a pure heater, and a lighter load.

0 of 6 steps

4 questions, graded as you go.

Chapter 5

## Power factor

An energy meter on a 120 V motor, and what the bill counts.

Locked 236 XP

### Power factor

A PZEM-004T energy meter set up as a 120 V shop motor beside the 12 V bench: power factor is P / S, 0.6 for the motor, 1.0 for a heater and worse at light load, and the energy counter only counts the real watts.

0 of 6 steps

4 questions, graded as you go.

Chapter 6

## Correction capacitors

A capacitor beside the motor that shrinks the line current.

Locked 218 XP

### Correction capacitors

A capacitor across the motor supplies its reactive current locally: the line drops from 23.9 to 14.4 mA while the motor still takes 24, half a capacitor does half the job, three times too much is worse than none, and 0.95 is the practical target.

0 of 6 steps

4 questions, graded as you go.

Chapter 7

## Boss build

Read a motor, size its capacitor, prove it on the bench.

Locked 249 XP

### Boss build: a motor's power bill

A 120 V shop motor on the energy meter and its 12 V twin on the bench: read its PF, size a correction capacitor for 1.0 and then for 0.95, prove it on the bench, and write the before and after sheet for your own motor.

0 of 7 steps

4 questions, graded as you go.

Syllabus

## Every lesson in the course

All 7 lessons, in order, each with what it covers. Any of them opens in the editor right away.

Chapter 1

### Phasors without fear

- Phasors without fear A scaled motor on 12 V AC: the resistor and the inductor read 7.2 V and 9.6 V, which add up to 12 V only as the sides of a right triangle. Phasors, the phase angle, and what frequency does to it.

Chapter 2

### Reactance

- Reactance: ohms that depend on frequency An inductor and a capacitor, each alone on 12 V at 60 Hz: both draw 30 mA, so both are worth 400 ohms. Double the frequency and the inductor halves its current while the capacitor doubles it.

Chapter 3

### Impedance

- Impedance: the whole opposition The motor bench with a capacitor waiting in series: Z = V / I = 500 ohms, the square root of R squared plus X squared, a capacitor that raises the current, one that cancels the inductor, and one that makes the load capacitive.

Chapter 4

### Real, reactive and apparent

- Real, reactive and apparent power Volts times amps is not watts on AC: the bench takes 0.287 VA, the resistor turns 0.171 W into heat and the inductor borrows 0.229 var and gives it back. The power triangle, a pure heater, and a lighter load.

Chapter 5

### Power factor

- Power factor A PZEM-004T energy meter set up as a 120 V shop motor beside the 12 V bench: power factor is P / S, 0.6 for the motor, 1.0 for a heater and worse at light load, and the energy counter only counts the real watts.

Chapter 6

### Correction capacitors

- Correction capacitors A capacitor across the motor supplies its reactive current locally: the line drops from 23.9 to 14.4 mA while the motor still takes 24, half a capacitor does half the job, three times too much is worse than none, and 0.95 is the practical target.

Chapter 7

### Boss build

- Boss build: a motor's power bill A 120 V shop motor on the energy meter and its 12 V twin on the bench: read its PF, size a correction capacitor for 1.0 and then for 0.95, prove it on the bench, and write the before and after sheet for your own motor.

Kits

## Build it on your bench too

Every lesson runs in the simulator with nothing to buy. When you want the real thing, these kits have the parts.

Have a kit already?

### Find your kit

Pick the starter kit you own and run every lesson in its manual with the same parts on the same pins.
See every kit

Questions

## About AC power

Is AC power free?

Yes. All 7 lessons of AC power are free and run in your browser, with nothing to install and no parts to buy before you start.

Do I need any parts?

No. Every circuit is built on a simulated breadboard, and the simulator checks each step as you go. When you want to build it for real, the same parts and wiring work on a real bench.

How long does AC power take?

About 6 hours: 7 lessons in 7 chapters, each one a few short steps. Your progress is kept, so you can stop after any lesson and pick up where you left off.

Where do I start?

With "Phasors without fear", and each lesson builds on the one before it. New to circuits? Electronics basics is the course that starts from zero.